STV Series - Diaphragm isolation solenoid valve
Orifice diameter 1.0 - 1.2mm
Description
2/2-ways diaphragm isolation solenoid valves with fluid separation.
A large selection of wetted materials and connection options allows a wide range of applications.
A 2/2-ways version with push-in fittings is available for this series. These connections allow PTFE or PFA hoses with an outside diameter of 2.0 mm.
Specifications
| 
            Type
         | 
            2/2-way normally closed 2/2-way normally open | 
| 
            Orifice diameter
         | 
            1.0 - 1.2 mm
         | 
| 
            Port Connection
         | 
            M6 | 1/4-28UNF | Push-In | Hose nozzles | Flange | Push-In fittings (for 2/2-way)
         | 
| 
            Rated voltage
         | 
            12 VDC | 24 VDC other voltages on request | 
| 
            Operating Pressure range
         | 
            input: -900 - 2000 mbar output (NC | NO): 0 - 500 mbar | 
| 
            Diaphragm material
         | 
            PTFE
         | 
| 
            Body material
         | 
            PEEK | PPS | PTFE | POM
         | 
| 
            Seal material
         | 
            Soft-Seal PTFE | Perfluoroelastomer (FFKM) | FPM
         | 
| 
            Other wetted materials
         | 
            PTFE | Ceramic - AL2O3 for 3/2 way
         | 
| 
            Fluid temperature range
         | 
            0 - 50°C (higher temperatures on request)
         | 
| 
            Ambient temperature range
         | 
            0 - 50°C (higher temperatures on request)
         | 
| 
            Power consumption
         | 
            1.7 - 2.9W (depending on model) | 
| 
            Operating mode
         | 
            100% ED
         | 
| 
            Mounting position
         | 
            Any
         | 
| 
            Fluid
         | 
            Resistant to neutral and aggressive liquids / gases (see resistance lists) | 
| 
            Dimensions
         | 
            Ø20.0 x 42.5 mm
         | 
Customizable to specific requirements (e.g. higher pressure range, different operating mode, higher temperature range, different operating voltage, different port connections, ...)
Downloads
- STV series data sheet 253 KB
 
		 
							
						